A force probe inside an electron microscope

Byeonghoon Lim builds quartz tuning fork AFM probes at Jeonbuk National University.

Talks and posters
DateMeetingFormSubject
2026.10IEDMS 2026, TaipeiOralDrift correction
2026ISPSA 2026PosterDrift correction
2025.121st Basic Science FestivalPosterThree surfaces
2025.11Korean Society of Surface AnalysisPosterThree surfaces
2025.08IWSPM 2025PosterCharged surfaces
Marked: paper D3-6 at the 31st IEDMS.

Quartz fork, gold-coated tip

A 32,768 Hz fork, read electrically, so no laser enters the chamber.

SEM micrograph at 100 times: one prong of the tuning fork with a fine tip reaching toward a sample surface
The tip, a thin line at lower left, approaching a sample. Scale bar 100 µm.
SEM micrograph at 50 times: both prongs of a quartz tuning fork, a tip attached to the upper prong
Both prongs of the fork, the tip on the upper one.

Vacuum doubles the Q-factor

A tipped fork swept through resonance in air, then in the evacuated chamber.

  • Vacuum, Q-factor 20,319
  • Air, Q-factor 9,568

Amplitude, V

Detuning from the peak, Hz

EnvironmentQ-factorPeak, HzAmplitude, VDrive, mV rms
Air9,56832,534.26.912130
Vacuum20,31932,542.26.71460
Measured 11 June 2026. Q-factor is the peak frequency over the width at half maximum.

How the tip is made

  1. Pull

    A quartz rod is heated with a laser and pulled to a point.

  2. Coat

    The point is coated with gold.

  3. Mount

    The rod is attached to one prong of the fork.

SEM micrograph at 10,000 times: the tapered end of the quartz tip, annotated 201.5 nanometres at the apex
The apex, about 200 nm across, at 10,000 times.

Drift between approach and retraction

On silicon in vacuum, the two curves disagree in position at equal amplitude.

−3.068 nm
Mismatch at 4.0 V in the raw curves
−0.350 nm
The same mismatch after alignment
+3.098 nm
Offset applied to every retraction point

Presented at IEDMS 2026. The residual still varies with amplitude level.

Three surfaces under the beam

Mica

A dielectric. Damping appears with the beam on.

Silicon

A semiconductor. Curves in vacuum and under the beam nearly coincide.

Gold

A conductor. Damping appears under the beam, as on mica.

Manuscript comparing the three in preparation.

View inside the SEM chamber: the probe arm reaching over the sample stage below the electron column
Inside the SEM chamber during a measurement.

Where to find me

Lab
Microscope-based Nanoscale Physics Lab, Department of Physics, Jeonbuk National University, Jeonju, Korea
Advisor
Prof. Sangmin An
Next
A master’s in physics from 2027, toward silicon MEMS processing